Moved without losing refrigerant
AC removal & refitting in Quba
In Quba, north-east Jeddah, residents need AC units moved when relocating or expanding. Alrabih's team carefully evacuates the refrigerant from the outdoor unit, caps the copper tubes securely, transports both units with full care, and installs fresh copper line pulled to a complete vacuum.
- Refrigerant saved
- Fresh copper
- Holes sealed
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When you need removal and refitting
- 1
Moving to a new home
You want to take your units to the new home without losing the refrigerant charge or arriving with a unit that no longer cools properly. The right removal keeps the charge locked in the outdoor unit until refitting.
- 2
Renovation or repainting
Contractors need a clear wall for painting or plastering. We remove the indoor unit after saving the refrigerant, and once the renovation is done, we refit and close old holes that would otherwise spoil the fresh wall finish.
- 3
Repositioning a unit in the same building
The current position may no longer suit new furniture, or the old wall core is in the wrong place. We move it to the better spot and plan the new copper and drain route before drilling anything.
Who it's for
Renovating your flat and need walls cleared
We remove indoor units after pump-down, seal old holes, then refit once finishing work is complete so your units are never handled by the renovation crew.
Ask on WhatsAppRelocating your business to new premises
We survey both premises, pump down, remove the units from the current site, then refit them at the new location with copper runs and drain lines suited to the new building layout.
Ask on WhatsApp
What the service covers
- Pump-down into outdoor unit
- Remove both units cap pipes
- Seal old wall holes
- Mueller copper insulated on site
- Vacuum test and start-up
How we work
How we work
- 1
Survey both sites
We visit the removal site and the new location to plan the copper route, drain line and run length, and tell you if new copper or extra materials are needed.
- 2
Pump down and remove
We run the unit in pump-down mode until all refrigerant moves into the outdoor unit, then close the service valves and remove both units carefully.
- 3
Seal holes and transport
We close the old wall cores with suitable material so they do not let in hot air or insects, then transport both units to the new location.
- 4
Refit, vacuum and start
We mount both units, run Mueller copper in runs of up to 30 metres without welded joints, vacuum the line, test the joints, then release the saved refrigerant and verify cooling with you present.
Proper removal or an unprepared one?
| Alrabih | The usual way | |
|---|---|---|
| Refrigerant | Saved by pump-down | Lost to the air |
| Copper pipes | Capped at removal | Open, moisture enters |
| Old holes | Sealed after removal | Left open, air leaks in |
| New-site copper | New Mueller, insulated | Old copper reused |
| Drain at new site | Drain fall planned at survey | Left to chance during fitting |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Quba is a rapidly developing district with a mix of modern villas and flats with constantly evolving infrastructure. Residents move between new and existing homes fairly often, and may need AC units relocated on purchase or rental. Rapid urban growth means electrical and drainage setups differ from house to house, so we inspect before installing. The spaces here are more open than older areas, making unit relocation and new copper line installation easier.
Quba is in north-east Jeddah, a rapidly developing district mixing modern villas and flats.
Most modern homes in Quba have separate split units, and electrical infrastructure varies due to rapid development.
The AC setup in Quba
- 1
Separate split unit per villa or flat section
Modern villas and flats in Quba typically have separate split units per area or room.
- 2
Relatively modern electrical infrastructure
Rapid development has equipped most modern homes with safe, suitable electrical points for modern AC units.
- 3
Reasonable outdoor spaces
Modern villa and flat design provides ample outdoor space to position outdoor units at various locations.
Before the visit
Before our visit in Quba
- 1
Specify the new location before contacting us
Tell us exactly where the new indoor and outdoor units will go so we can accurately estimate the copper run needed.
- 2
Verify the electrical point is sound
Check that the electrical point at the new unit location is safe and capable of handling the AC load.
- 3
Clear pathways from entrance to site
Ensure the team can freely access from the home entrance to both the old and new unit locations without obstruction.
More districts for AC removal & refitting
Other services in Quba
FAQ
Questions about AC removal & refitting
Can the old copper pipes be reused at the new site?
It depends on the condition of the pipes and the layout at the new site. If the pipes are free of oxidation and insulation cracking, and the length fits the new run, they can be reused after inspection. If the new site needs a longer route or the existing pipes show wear, fresh Mueller copper pipe at 99% pure copper is run to suit the new layout. The site survey decides.
Why not just remove the unit without pumping down first?
Before any connection is opened, the compressor is run to pump the refrigerant charge into the outdoor unit and the service valves are closed on it. If the connections are opened first, the refrigerant escapes into the air and is lost entirely, which is both costly and harmful to the environment. Pumping down first keeps the full charge sealed inside the outdoor unit, ready to use at the new site.
What happens to the old wall hole after the unit is removed?
Once the pipes and cable are pulled out, the hole is cleared of insulation remnants and sleeve material, then sealed with a filler suited to the wall type, whether concrete, brick or gypsum board. The aim is a tight closure that stops humid air and insects from entering and leaves the wall surface clean before the site is handed back.
Can a unit be moved to a different floor in the same building?
Yes, but moving to a different floor means a completely new pipe route, a different cable length, and possibly a changed drain line fall. The site survey defines the pipe path, the required run length and the outdoor unit position. Mueller copper pipe at 99% pure copper is then laid along a route that accounts for the floor difference, and a vacuum test and pressure test are carried out before the unit is started.
Can a unit be moved to a different floor in the same building?
Yes, but a different floor changes the copper run length, the drain route and where the outdoor unit is fixed. At the survey we establish whether extra copper is needed and where the drain can fall correctly, then plan the full route before any removal begins.
We bought a new villa in Quba, can we move the AC from our old home?
Yes, we safely move the unit from your old home to the new one. We evacuate the refrigerant, cap the lines, transport both units, and install fresh copper line pulled to a complete vacuum.
Quba has new infrastructure, does this affect installation?
The modern infrastructure and new wiring are much better for installation. We inspect the electrical point and drainage first to confirm they suit the new unit.
The district is growing fast, can you easily reach Quba with your team?
Yes, we cover all of Quba. The modern roads and planned expansion make it easy for the team to travel and reach sites.
Does new copper run need special measurement in modern villas?
We measure the distance precisely between both units. Most modern villas in Quba have fairly uniform layouts, making it easy to calculate the required length.