Cold rooms kept running
Cold rooms in Al Sawari
In Al Sawari, north Jeddah, restaurants, cafés and small shops depend on cold rooms to preserve their stock. Alrabih's team inspects the evaporator, condenser, thermostat and door seals to restore temperature stability and protect the goods.
- Accurate diagnosis
- Clean evaporator
- Sealed door
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When your cold room needs attention
- 1
Room not holding temperature
The temperature climbs slowly even though the unit keeps running, or the products inside are warmer than they should be. The cause could be the evaporator, condensing unit, refrigerant level or controller, and only a site check tells which.
- 2
Evaporator icing up and stopping
Ice builds on the evaporator until airflow stops and cooling fails. The cause is usually in the defrost circuit, its sensor or the evaporator fan. Jeddah's humid air speeds up icing when anything in that circuit is not working correctly.
- 3
Door letting cold air escape
A worn or deformed door seal lets warm humid air in, overloading the refrigeration unit and speeding up evaporator icing. If the door frame heater has failed, moisture builds on the frame and the door becomes hard to open.
Who it's for
Running a restaurant or central kitchen cold room
We check the evaporator, defrost circuit and door seal in your kitchen cold room and fix any fault before your food stock is put at risk.
Ask on WhatsAppOperating a freezer room in a warehouse or retail outlet
We find the cause of temperature loss in your freezer room, inspect the rooftop condensing unit, controller and alarm, and complete a full running test before we leave.
Ask on WhatsApp
What the service covers
- Evaporator check and clean
- Defrost circuit and sensors
- Door seal and frame heater
- Rooftop condensing unit inspection
- Controller and temperature alarm
How we work
How we work
- 1
Describe the fault
WhatsApp us what you see: the temperature showing on the controller, whether the unit is running or not, and the type of stock inside the room.
- 2
Site check and diagnosis
The technician checks the evaporator, condensing unit, defrost circuit, controller and door seal, then identifies the actual cause of the temperature loss before starting any work.
- 3
Repair and replacement
We fix what the diagnosis found: clean the evaporator, repair the defrost circuit, replace the seal or adjust the refrigerant charge to the type written on the unit nameplate.
- 4
Test and handover
We run the room and watch the temperature until it reaches the set value, confirm the alarm and controller are working, then hand you a report of what was done.
Systematic maintenance or a quick temporary fix?
| Alrabih | The usual way | |
|---|---|---|
| Diagnosis | Root cause first | Symptom fixed only |
| Evaporator | Checked and cleaned | Ignored until it stops |
| Door seal | Checked, adjusted or replaced | Left until obviously leaking |
| Controller and alarm | Tested before leaving | Not checked |
| Post-visit report | Written record of work done | Verbal summary only |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Sawari mixes residential buildings with small and medium commercial shops and restaurants tightly packed together. The cold rooms here are often fitted into confined spaces behind shops or kitchens, and they bear a heavy daily use cycle because of constant customer flow. The coastal heat and humidity raise the load on the condenser, so regular maintenance and careful cleaning of the internal and external coils is essential.
Al Sawari lies in north Jeddah as a dense commercial residential zone with diverse restaurants and shops in close proximity.
Most cold rooms here are small to medium units with the condensing unit mounted on the shop's roof or exterior wall.
The AC setup in Al Sawari
- 1
Compact integral cold room unit
Most small shops and restaurants here use compact integral cold rooms with the condenser mounted easily on the roof.
- 2
Separate cold room with remote condenser
Some larger restaurants use a separate indoor chamber with a remote condenser unit mounted on the wall or roof.
- 3
Multiple cold rooms for larger merchants
Larger merchants in the area may run two or more cold rooms, each with its own controller and separate condenser.
Before the visit
Before our visit in Al Sawari
- 1
Let us know your closing or quietest time
Agree with us on the best time for maintenance so daily operations and customers are not disrupted.
- 2
Ensure the team can reach the outdoor condenser
If the condenser is on the roof or a high wall, check that a ladder or safe roof access is available before the visit.
- 3
Disconnect power if deep maintenance is needed
For internal or external repairs, show us where the main power switch is for the cold room to ensure safety.
More districts for Cold rooms
Other services in Al Sawari
FAQ
Questions about Cold rooms
Why does the temperature rise even though the unit runs all the time?
Continuous running does not mean correct operation. Common causes include a refrigerant leak that reduces the charge, heavy frost on the evaporator coil blocking airflow, or a fault in the rooftop condensing unit raising head pressure. A site survey identifies the actual cause before any work begins.
How do I know if the defrost cycle is working properly?
Clear signs of a defrost fault include thick frost covering the full evaporator coil, a gradual temperature rise while the unit keeps running, and water pooling on the floor instead of draining away. The check covers the heater element, the defrost sensor and the controller, as the fault can lie in any of these parts.
What does a preventive visit for a cold room cover?
A preventive visit covers a pressure check on the refrigeration circuit, cleaning the condenser and evaporator coils, inspecting door seals and frame heaters, testing the controller and alarm, and checking copper pipe connections. The aim is to find a developing fault before it affects the room temperature and the stock inside.
What is the difference between a preventive visit and a repair visit?
A preventive visit is carried out on a unit that is running normally: the purpose is inspection, cleaning and finding early signs of wear before they become a breakdown. A repair visit is requested when an actual fault appears, such as a rising temperature, a stopped compressor or excessive coil icing. Diagnosis comes first, then the required work is defined.
Does Jeddah's rooftop heat affect the condensing unit's performance?
Yes. In summer, Jeddah rooftop surfaces reach very high temperatures, which raises condensing pressure, stresses the compressor and reduces cooling capacity. Regular cleaning of the condenser coil to remove the dust and salt that cling to the fins is essential, not optional. A site survey determines whether the unit's position or the airflow around it is making the problem worse.
How often should a restaurant's cold room be cleaned?
Given the heavy daily use in restaurants, we recommend inspecting and cleaning the coils at least every three months, with more frequent checks during summer.
The shop is busy all day, how can we fit in maintenance?
We aim to work during closing hours or quieter periods, and we coordinate with you in advance to pick a time that suits your operations.
The humid coastal air affects the cold room, how do we keep it stable?
Yes, coastal humidity speeds up mould and rust on the external coils, so we clean them regularly and check the door seals.
The thermostat seems inaccurate, how do we diagnose it?
We inspect the controller, sensors and electrical connections on every visit, and test the actual temperature reading against the desired setting.












































































