Find the leak first
Refrigerant charging in Al Aziziyah
In Al Aziziyah, central Jeddah, AC units and commercial refrigerators are charged with the correct refrigerant after checking for leaks. Alrabih's team repairs any leak first, vacuums the circuit, then charges to the unit's nameplate type and amount.
- Leak located
- Vacuum and test
- Accurate charge
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
Signs the charge is low
- 1
Weak cooling and a compressor that runs on
The unit runs for hours without bringing the temperature down, or cools very slowly. This is usually the first sign the charge is low and the circuit can no longer move heat efficiently.
- 2
Frost on the pipes or evaporator coil
Ice on the thin pipe or on the evaporator coil points to low refrigerant pressure. Continued running can damage the coil. Where the frost forms helps the technician narrow down the problem area.
- 3
A refrigerator or cold room that will not hold temperature
In commercial or industrial refrigeration equipment, a rising cabinet temperature means stock at risk. Low refrigerant is one possible cause, and confirming it needs pressure readings and a circuit check on site.
Who it's for
Your window or portable unit cools slowly
We check circuit pressure, locate and repair the leak, then vacuum and charge to the type shown on your unit's nameplate.
Ask on WhatsAppYour cold room or commercial fridge will not hold temperature
We measure pressure, identify why the cabinet temperature is rising, repair any leak found, then charge to the correct refrigerant type for that unit.
Ask on WhatsApp
What the work covers
- Pressure check and leak location
- Leak repair before charging
- Vacuum and tightness test
- Charge to nameplate refrigerant
- Run test and performance check
How we work
How we work
- 1
Inspect and locate leak
The technician measures circuit pressure and checks joints and components that corrode in Jeddah's humid, salty air, pinpointing the leak before any other step.
- 2
Repair the leak
The technician repairs the leak point, whether a loose joint, a cracked pipe or corrosion in part of the circuit. The unit is not charged until the repair is confirmed tight.
- 3
Vacuum and pressure test
The circuit is evacuated with a vacuum pump to remove air and moisture, then the reading is watched to confirm pressure holds before refrigerant is introduced.
- 4
Charge and run
The unit is charged to the nameplate type and amount, then run and checked for proper performance on site before handover.
Fix the leak or just top it up?
| Alrabih | The usual way | |
|---|---|---|
| The leak | Found and fixed first | Often ignored |
| Vacuum | Before every charge | Sometimes skipped |
| Refrigerant type | As the nameplate states | May be mixed or swapped |
| Compressor | Protected by correct charge | Worn by wrong charge |
| Refrigeration equipment | AC, fridges and cold rooms | Usually AC only |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Aziziyah is a central Jeddah district mixing residential and commercial uses, with villas, shops, food-display chillers, small warehouses and groundwater wells. Cooling systems here vary from villa AC to shop refrigerators and storage units, and each type needs precise leak checks because the source depends on the device type and its use.
Al Aziziyah lies in central Jeddah, a mixed residential and commercial district with shops, villas and display chillers.
Systems here use different refrigerant types depending on the device, and commercial fridges often need repeated charging if there is a leak in the external connections.
The AC setup in Al Aziziyah
- 1
Display and freezer units in food shops
Food shops in Al Aziziyah rely on display chillers and small freezer units that need regular refrigerant charging.
- 2
Villa and apartment AC systems
Villas and flats in the area typically have split AC with medium-length copper runs.
- 3
Small storage and cooling rooms
Small warehouses and storage areas may have package cooling units or compact freezer rooms needing regular inspection.
Before the visit
Before our visit in Al Aziziyah
- 1
Specify the device type and refrigerant size
Tell us whether it is an AC unit, display fridge or freezer, and read the refrigerant type from the nameplate on the device.
- 2
Provide access to the outdoor unit or cooling coil
Ensure the team can easily reach the outdoor unit or cooling coil, especially if the fridge is in a tight corner of the shop.
- 3
Coordinate the timing with your working hours
If the device is in a shop, let us know the best time to visit so we do not disrupt your trade, as we may need to shut it down briefly.
More districts for Refrigerant charging
Other services in Al Aziziyah
FAQ
Questions about Refrigerant charging
Can you just add refrigerant without looking for the leak?
A sealed refrigerant circuit does not consume refrigerant. A low charge means there is a leak somewhere. Adding refrigerant without finding and repairing that leak brings the same fault back quickly and can damage the compressor. The correct sequence is always to locate the leak, repair it, pull a vacuum on the circuit, and then charge to the type and quantity shown on the unit's nameplate.
Where does refrigerant leak in commercial refrigeration equipment?
The most common points are expansion fittings and restrictions on the liquid line, flare joints at the evaporator and condenser, and service valves where the rubber seals have aged. In commercial refrigeration, old copper pipe welds weakened by continuous compressor vibration are also a frequent source. The exact location is found during the site inspection.
Does the refrigerant type affect how the unit performs?
Yes. Every unit is designed for a specific refrigerant type with defined operating pressures and heat transfer properties. Using a different type changes those pressures and can either overload the compressor or reduce cooling output. For this reason the unit is always charged with the exact type shown on its nameplate and no substitute is used.
Is the charging work different for a home AC unit and a commercial refrigerator?
Yes, they differ in several ways. Commercial refrigeration units operate at pressures and with refrigerant types distinct from those in air conditioners, and their target temperatures are much lower. The pipe circuits are also longer and often include multiple distributors and valves that require careful inspection before vacuuming and charging. The nature of each circuit determines the procedure.
Is the charging work different for a home AC unit and a commercial refrigerator?
The core steps are the same: locate the leak, repair it, vacuum the circuit, then charge to the nameplate type. Commercial refrigeration units sometimes have additional valves and components that require a different inspection approach. What each unit needs is determined by the technician on site after pressure readings and a circuit check.
My shop's display fridge is not cooling properly, what causes this?
The refrigerant may be low due to a leak in the copper lines or threaded joints. We inspect the fridge, repair any leak, then charge the correct refrigerant.
Shops here are close together and stay open all day, can you charge my fridge while I'm trading?
Yes, but we need to arrange this in advance because charging takes time. We agree on a quieter hour in the shop, and may need to turn off the fridge briefly.
Does Jeddah's high humidity affect refrigerant in shop fridges?
High humidity accelerates corrosion of copper joints and metal components over time, potentially causing leaks. Regular inspection catches leaks early.
Is there a difference in refrigerant type between different fridge models?
Yes, commercial fridges may use R404A or R134a, while AC systems often use R410A. We check your unit's nameplate to charge the correct type.