Find the leak first
Refrigerant charging in Al Sharqiyah
In Al Sharqiyah, east Jeddah, residential and villa blocks suffer weak cooling when refrigerant leaks slowly. Alrabih's team uses a sensitive laser detector to pinpoint the leak precisely, repairs it skillfully, then vacuums and charges to the unit's original specs.
- Leak located
- Vacuum and test
- Accurate charge
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
Signs the charge is low
- 1
Weak cooling and a compressor that runs on
The unit runs for hours without bringing the temperature down, or cools very slowly. This is usually the first sign the charge is low and the circuit can no longer move heat efficiently.
- 2
Frost on the pipes or evaporator coil
Ice on the thin pipe or on the evaporator coil points to low refrigerant pressure. Continued running can damage the coil. Where the frost forms helps the technician narrow down the problem area.
- 3
A refrigerator or cold room that will not hold temperature
In commercial or industrial refrigeration equipment, a rising cabinet temperature means stock at risk. Low refrigerant is one possible cause, and confirming it needs pressure readings and a circuit check on site.
Who it's for
Your window or portable unit cools slowly
We check circuit pressure, locate and repair the leak, then vacuum and charge to the type shown on your unit's nameplate.
Ask on WhatsAppYour cold room or commercial fridge will not hold temperature
We measure pressure, identify why the cabinet temperature is rising, repair any leak found, then charge to the correct refrigerant type for that unit.
Ask on WhatsApp
What the work covers
- Pressure check and leak location
- Leak repair before charging
- Vacuum and tightness test
- Charge to nameplate refrigerant
- Run test and performance check
How we work
How we work
- 1
Inspect and locate leak
The technician measures circuit pressure and checks joints and components that corrode in Jeddah's humid, salty air, pinpointing the leak before any other step.
- 2
Repair the leak
The technician repairs the leak point, whether a loose joint, a cracked pipe or corrosion in part of the circuit. The unit is not charged until the repair is confirmed tight.
- 3
Vacuum and pressure test
The circuit is evacuated with a vacuum pump to remove air and moisture, then the reading is watched to confirm pressure holds before refrigerant is introduced.
- 4
Charge and run
The unit is charged to the nameplate type and amount, then run and checked for proper performance on site before handover.
Fix the leak or just top it up?
| Alrabih | The usual way | |
|---|---|---|
| The leak | Found and fixed first | Often ignored |
| Vacuum | Before every charge | Sometimes skipped |
| Refrigerant type | As the nameplate states | May be mixed or swapped |
| Compressor | Protected by correct charge | Worn by wrong charge |
| Refrigeration equipment | AC, fridges and cold rooms | Usually AC only |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Sharqiyah is a mature residential district with mid-rise blocks and mixed villas with ground-floor shops, and its buildings are older than Taiba but copper runs remain prone to slow leaks from seasonal pressure. Many owners here have limited budgets and prefer a complete solution first time rather than repeated repairs.
Al Sharqiyah lies in east Jeddah, a settled residential district of mixed apartment blocks and villas with ground-level shops.
Most AC units in Al Sharqiyah are older splits or simple central systems, with slow leaks far more common than sudden ruptures.
The AC setup in Al Sharqiyah
- 1
Older split systems in residential blocks
Most residential blocks in Al Sharqiyah have older splits, one per flat, with slow leaks being very common.
- 2
Villas with basic multi-split
Villas here use basic multi-split without complex central systems, making leak detection simpler but increasing connection points.
- 3
Visible runs on walls and balconies
Copper runs are usually visible on external walls and balconies, making access easier but leaks may be more apparent.
Before the visit
Before our visit in Al Sharqiyah
- 1
Switch off power to the unit before visit
For safety, turn off power to the unit before the team arrives to inspect the circuit and repair the leak.
- 2
Expose copper runs if they are covered
If copper runs are covered by insulation or conduits, ask the team to expose them at suspected leak points to speed inspection.
- 3
Ensure easy access to the outdoor unit
Outdoor units here are on balconies or nearby roofs, clear the area around them and remove obstacles for the team's work.
More districts for Refrigerant charging
Other services in Al Sharqiyah
FAQ
Questions about Refrigerant charging
Can you just add refrigerant without looking for the leak?
A sealed refrigerant circuit does not consume refrigerant. A low charge means there is a leak somewhere. Adding refrigerant without finding and repairing that leak brings the same fault back quickly and can damage the compressor. The correct sequence is always to locate the leak, repair it, pull a vacuum on the circuit, and then charge to the type and quantity shown on the unit's nameplate.
Where does refrigerant leak in commercial refrigeration equipment?
The most common points are expansion fittings and restrictions on the liquid line, flare joints at the evaporator and condenser, and service valves where the rubber seals have aged. In commercial refrigeration, old copper pipe welds weakened by continuous compressor vibration are also a frequent source. The exact location is found during the site inspection.
Does the refrigerant type affect how the unit performs?
Yes. Every unit is designed for a specific refrigerant type with defined operating pressures and heat transfer properties. Using a different type changes those pressures and can either overload the compressor or reduce cooling output. For this reason the unit is always charged with the exact type shown on its nameplate and no substitute is used.
Is the charging work different for a home AC unit and a commercial refrigerator?
Yes, they differ in several ways. Commercial refrigeration units operate at pressures and with refrigerant types distinct from those in air conditioners, and their target temperatures are much lower. The pipe circuits are also longer and often include multiple distributors and valves that require careful inspection before vacuuming and charging. The nature of each circuit determines the procedure.
Is the charging work different for a home AC unit and a commercial refrigerator?
The core steps are the same: locate the leak, repair it, vacuum the circuit, then charge to the nameplate type. Commercial refrigeration units sometimes have additional valves and components that require a different inspection approach. What each unit needs is determined by the technician on site after pressure readings and a circuit check.
My unit cools but the electricity bill has jumped, does a leak increase consumption?
Yes, low refrigerant forces the compressor to work harder and longer, raising consumption noticeably. Fixing the leak and charging correctly cuts the bill.
My copper runs are visible, can I see the leak myself?
Small leaks are nearly impossible to spot with the naked eye, even a pinhole leaves no obvious trace. We use an electronic detector sensitive enough to pinpoint exactly where it is.
Summer heat causes more faults, is it better to repair a leak in winter?
The leak exists either way, but high heat makes poor performance more obvious. We recommend immediate repair any time to prevent further damage.
After charging, how long do I wait before using the unit normally?
After repair and proper charging, the unit is ready for immediate use with no additional wait time.