Charged right, not just topped up
Split AC refrigerant charging in Al Mawaddah
Split AC refrigerant charging in Al Mawaddah focuses on precise leak tracing in a densely urban setting, where units are packed densely and often share services.
- Leak found first
- Vacuum and test
- Correct charge
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When your split needs a refrigerant charge
- 1
Weak cooling with a clean filter
If the filter is clean and the compressor is running but the air from the indoor unit is barely cool, the cause is usually low refrigerant from a leak at the flare joints or the outdoor service valves.
- 2
Frost on the pipes or unusual water drips
Frost on the large pipe at the indoor unit, or water dripping from the unit in an unusual way, means refrigerant pressure has dropped below the range set by the manufacturer. The inspection finds the leak before any charging begins.
- 3
A split that was moved and refitted
When a split is removed for painting, renovation or a room move, the flare joints are disconnected and remade. These joints are the most likely source of a leak after refitting, and the system needs a careful check, a vacuum and a fresh charge.
Who it's for
Your bedroom split cools only at night
We find and fix the leak at the flare joints, then vacuum and charge to the nameplate refrigerant type.
Ask on WhatsAppYour split was removed for renovation and refitted
We inspect every remade flare joint, vacuum the full line, then charge and confirm cooling has returned.
Ask on WhatsApp
What the job covers
- Check flare joints and valves
- Repair or remake flare
- Vacuum line and pressure test
- Charge to nameplate refrigerant type
- Run unit confirm cooling
How we work
How we work
- 1
Describe the fault
Tell us on WhatsApp what is happening and send a photo of the outdoor unit nameplate so we know the refrigerant type before we arrive.
- 2
Inspect and find the leak
The technician checks the flare joints at the indoor unit and the service valves at the outdoor unit and locates the leak before taking any further step.
- 3
Repair and vacuum
We tighten or remake the flare joint as its condition requires, then vacuum the line and watch the pressure hold to confirm the line is tight.
- 4
Charge and run
We charge with the nameplate type at the amount the inspection determines, then run the unit and confirm that cooling has returned to the normal level.
Fix the leak first or just top it up?
| Alrabih | The usual way | |
|---|---|---|
| The leak | Found and fixed first | Ignored, charged over it |
| Flare joint | Checked, remade if needed | Not checked |
| Vacuum | Before every charge | Often skipped |
| Refrigerant type | Nameplate only | Whatever is available |
| Line moisture | Removed by vacuum | Left inside the line |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Mawaddah is a densely packed district of villas and mid-rise apartments with limited streets and closely clustered developments. Split unit density here is very high, with copper lines mounted on shared walls or projects very close together. Moisture and dust from the streets and tight spaces accelerate corrosion in joints and lines. Precise leak location is critical here because urban congestion restricts repair and charging options.
Al Mawaddah sits in east Jeddah, a densely packed residential district of closely spaced villas and apartment blocks.
Multiple split units crowd each villa and block, with lines mounted on narrow external walls because gaps between buildings are tight.
The AC setup in Al Mawaddah
- 1
Multiple units on shared walls
Each villa and block has several split units mounted on narrow external walls due to urban density.
- 2
Short but densely packed copper lines
Lines are relatively short between indoor and outdoor units, but sheer quantity in the tight space creates high density.
- 3
Multiple compressors on one property
A villa or block may have two or more compressors depending on the number of indoor and outdoor zones.
Before the visit
Before our visit in Al Mawaddah
- 1
Specify which unit needs charging
Tell us the location of the specific indoor and outdoor unit needing charging, so we identify it correctly among the others.
- 2
Provide safe working space around the unit
Make sure our team can stand safely around the outdoor unit without obstruction or hazard on the shared wall.
- 3
Switch off power to the target unit
If this unit is one of several, make sure power is switched off to that specific unit only.
More districts for Split AC refrigerant charging
Other services in Al Mawaddah
FAQ
Questions about Split AC refrigerant charging
Does the split have to come off the wall to be recharged?
Usually not. Charging is done at the service valve on the outdoor unit, and if the leak is at the flare joints behind the indoor unit we reach them by lifting the lower cover or tilting the unit on its bracket. It only comes down when the joint is inside the wall.
Where do leaks usually occur in a wall split?
The most common points in a wall split are the flare joints at the indoor unit, which loosen over time from vibration, and the service valves at the outdoor unit. In Jeddah's humid and salty air, oxidation at copper connections can develop faster, which raises the chance of a leak.
Does the charging process differ when a split has been moved?
When a split is moved, the flare joints are disconnected and remade, and this is when air and moisture enter the line. A full vacuum before charging becomes especially important, and the technician checks every remade flare joint before the line is closed.
Why does my split cool only at night?
This is a common sign of low refrigerant. At night, lower outdoor air temperature lets the compressor partly compensate for the shortage. During Jeddah's daytime heat, the reduced charge is not enough and cooling weakens or stops. The inspection confirms whether this is the cause or whether another factor such as the compressor or capacitor is involved.
Does the length of the copper pipe run affect how much refrigerant is needed?
Yes, a longer copper pipe run between the two units requires more refrigerant. The site inspection measures the actual run length, and the technician sets the charge amount based on the nameplate figure and the installed pipe length.
Units are very close together, does one interfere with another?
No, but units run at higher load due to congestion, which can accelerate leaks. We inspect each unit separately and diagnose its individual leak.
Lines are on shared walls, how do you repair a leak?
We locate the exact leak with a detector, then repair the fitting or cut out the leaky section as needed. Occasionally we coordinate with neighbours.
Does dust and humidity here speed up corrosion?
Very much so, dust and moisture settle on fittings and metals, accelerating corrosion. Regular cleaning and inspection are essential here.
After repairing the leak and charging, is the problem solved?
If we have sealed the original leak properly and fully vacuumed and charged the line correctly, the problem should be solved. However, annual checks help catch new issues.