Charged right, not just topped up
Split AC refrigerant charging in Al Shiraa
In Al Shiraa, north Jeddah, Split AC refrigerant charging means finding and fixing the leak first, then vacuuming the line and charging it to the nameplate type and amount to prevent the fault returning.
- Leak found first
- Vacuum and test
- Correct charge
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When your split needs a refrigerant charge
- 1
Weak cooling with a clean filter
If the filter is clean and the compressor is running but the air from the indoor unit is barely cool, the cause is usually low refrigerant from a leak at the flare joints or the outdoor service valves.
- 2
Frost on the pipes or unusual water drips
Frost on the large pipe at the indoor unit, or water dripping from the unit in an unusual way, means refrigerant pressure has dropped below the range set by the manufacturer. The inspection finds the leak before any charging begins.
- 3
A split that was moved and refitted
When a split is removed for painting, renovation or a room move, the flare joints are disconnected and remade. These joints are the most likely source of a leak after refitting, and the system needs a careful check, a vacuum and a fresh charge.
Who it's for
Your bedroom split cools only at night
We find and fix the leak at the flare joints, then vacuum and charge to the nameplate refrigerant type.
Ask on WhatsAppYour split was removed for renovation and refitted
We inspect every remade flare joint, vacuum the full line, then charge and confirm cooling has returned.
Ask on WhatsApp
What the job covers
- Check flare joints and valves
- Repair or remake flare
- Vacuum line and pressure test
- Charge to nameplate refrigerant type
- Run unit confirm cooling
How we work
How we work
- 1
Describe the fault
Tell us on WhatsApp what is happening and send a photo of the outdoor unit nameplate so we know the refrigerant type before we arrive.
- 2
Inspect and find the leak
The technician checks the flare joints at the indoor unit and the service valves at the outdoor unit and locates the leak before taking any further step.
- 3
Repair and vacuum
We tighten or remake the flare joint as its condition requires, then vacuum the line and watch the pressure hold to confirm the line is tight.
- 4
Charge and run
We charge with the nameplate type at the amount the inspection determines, then run the unit and confirm that cooling has returned to the normal level.
Fix the leak first or just top it up?
| Alrabih | The usual way | |
|---|---|---|
| The leak | Found and fixed first | Ignored, charged over it |
| Flare joint | Checked, remade if needed | Not checked |
| Vacuum | Before every charge | Often skipped |
| Refrigerant type | Nameplate only | Whatever is available |
| Line moisture | Removed by vacuum | Left inside the line |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Shiraa's buildings are relatively modern and spread across wide plots, so most villas and newer flats have high-efficiency split units. The intense heat and coastal humidity in north Jeddah put stress on the cooling system and speed up wear on pipe joints, especially if the unit is older or was installed without tight standards. Finding the leak calls for precise diagnostic equipment and expertise in handling high-pressure refrigeration systems.
Al Shiraa lies in north Jeddah, a district of modern villas and apartment blocks on separate plots with wide streets.
Most units in Al Shiraa are split systems mounted on external walls or open roofs, making the outdoor unit easy to reach during diagnosis and charging.
The AC setup in Al Shiraa
- 1
Split mounted on exposed external walls
Outdoor units are mounted openly on villa and flat walls, making access and diagnosis straightforward.
- 2
Open roofs for larger units
Some larger villas mount units on open roofs, providing ample workspace for the team and equipment.
- 3
High-efficiency cooling systems
Most modern units in Al Shiraa require high standards in charging and maintenance to keep their efficiency.
Before the visit
Before our visit in Al Shiraa
- 1
Confirm team access to the outdoor unit
Check that the outdoor unit is safely reachable and does not require a long ladder or risky climbing before the visit.
- 2
Ensure stable power supply for diagnosis
Diagnostic equipment needs stable power. Confirm the unit is properly connected and there are no issues with the circuit breaker.
- 3
Clear the space around the outdoor unit
Remove any furniture or plants that might obstruct team access or the unit's natural airflow.
More districts for Split AC refrigerant charging
Other services in Al Shiraa
FAQ
Questions about Split AC refrigerant charging
Does the split have to come off the wall to be recharged?
Usually not. Charging is done at the service valve on the outdoor unit, and if the leak is at the flare joints behind the indoor unit we reach them by lifting the lower cover or tilting the unit on its bracket. It only comes down when the joint is inside the wall.
Where do leaks usually occur in a wall split?
The most common points in a wall split are the flare joints at the indoor unit, which loosen over time from vibration, and the service valves at the outdoor unit. In Jeddah's humid and salty air, oxidation at copper connections can develop faster, which raises the chance of a leak.
Does the charging process differ when a split has been moved?
When a split is moved, the flare joints are disconnected and remade, and this is when air and moisture enter the line. A full vacuum before charging becomes especially important, and the technician checks every remade flare joint before the line is closed.
Why does my split cool only at night?
This is a common sign of low refrigerant. At night, lower outdoor air temperature lets the compressor partly compensate for the shortage. During Jeddah's daytime heat, the reduced charge is not enough and cooling weakens or stops. The inspection confirms whether this is the cause or whether another factor such as the compressor or capacitor is involved.
Does the length of the copper pipe run affect how much refrigerant is needed?
Yes, a longer copper pipe run between the two units requires more refrigerant. The site inspection measures the actual run length, and the technician sets the charge amount based on the nameplate figure and the installed pipe length.
My split only cools at night, is that a refrigerant leak?
It could be a line leak or a compressor fault. We diagnose the unit with specialist equipment and pinpoint the source before any charging.
Do I need to fix the leak before topping up the refrigerant?
Yes, fixing the leak first is essential, or the refrigerant will escape again within weeks. After the fix, we vacuum the line and charge it to the correct amount per the unit's nameplate.
Our heat is intense, does that weaken the refrigerant?
The intense heat and coastal humidity in north Jeddah increase pressure on the system and speed up wear on joints and pipes, so regular checks and maintenance are important.
How do you ensure the charged amount is correct?
We read the nameplate data and use an electronic scale to measure the charged amount precisely before start-up.