Freezer and dual-temp rooms
Cold & freezer room installation in Breiman
In Breiman, east Jeddah, cold and freezer rooms are installed for meat, fish, poultry and frozen goods warehouses. Alrabih's team designs the room to match your stock and installs it with thick insulation, frost-resistant flooring and a heated door frame that will not seize.
- Frost-proof floor
- Auto defrost
- Two-zone layout
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
Who needs a specialist freezer room?
- 1
Stock that needs sub-zero cold
Meat, poultry, fish and ice cream spoil if the temperature rises even briefly above the required level. A freezer room is built to hold that level continuously, not simply to cool.
- 2
One room, two temperature zones
Large restaurants and hotels usually need a chiller section and a freezer section side by side. We build both wings with separate insulation, independent refrigeration units and an insulated inner door, so neither zone affects the other's temperature.
- 3
Expanding an existing facility
If your current cold room no longer holds all your stock, or you need to add a freezer section beside it, we survey the site and propose the most practical way to expand with as little disruption to your operation as possible.
Who it's for
Opening a restaurant that needs a freezer room
We survey your kitchen and build the freezer room with frost-rated insulation panels, an insulated floor and a tight-sealing door.
Ask on WhatsAppNeed a chiller wing and a freezer wing together
We build both wings with separate insulation, independent refrigeration units and an insulated inner door between them.
Ask on WhatsApp
What the installation covers
- Freezer-rated insulation panels
- Insulated floor vapour barrier
- Heated frame tight-sealing door
- Evaporator with electric defrost
- Condensing unit temperature controller
How we work
How we work
- 1
Site survey
We visit the site, learn the stock type and required temperature, measure the available space, and decide the right insulation thickness and refrigeration system from what we find.
- 2
Design and supply
We draw the room layout including pipe and cable routes, then have the panels, doors and equipment ready before installation begins.
- 3
Installation and connection
We fit the panels, insulated floor and door, then run and insulate the copper pipes, vacuum the line and pressure-test it before starting the system. Mueller copper in runs of up to 30 metres without welded joints where the layout calls for it.
- 4
Start-up and handover
We run the system and watch the room reach its target temperature, confirm the defrost cycle works and the door seals properly, then explain the controls to the person responsible for the facility.
Specialist install or an unconsidered one?
| Alrabih | The usual way | |
|---|---|---|
| Floor | Insulated with vapour barrier | Plain floor that cracks |
| Door frame | Heated to prevent seizure | Freezes and warps |
| Evaporator | Scheduled electric defrost | Ice blocks the airflow |
| Insulation | Thickness set at survey | Same thickness for every room |
| Anteroom | Buffer zone reduces air ingress | Direct door into freezer |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Breiman is a spacious industrial and commercial district with modern warehouses and workshops, and cold rooms here need high insulation because east Jeddah's summer temperatures are extreme and coastal humidity reduces the evaporator's effective capacity. Large warehouse floors must handle heavy drainage of meltwater and condensation, and electrical supply must be stable for a high-power compressor.
Breiman sits in Jeddah's industrial east, a district of spacious warehouses and workshops in modern buildings.
Most freezer rooms here are large capacity with powerful compressors and central drainage systems to handle the heavy daily load.
The AC setup in Breiman
- 1
Single-evaporator freezer room
Small to medium warehouses in Breiman typically need one freezer room with a single evaporator and compressor unit housed outside the room.
- 2
Medium cold room with two temperature zones
Some warehouses need multiple temperature zones within one room, so we install a separate evaporator per zone with a thermostatic expansion valve.
- 3
Large-capacity freezer with automatic defrost cycle
Large warehouses in Breiman require powerful compressors and automatic defrost cycles to minimise frost build-up on the evaporator.
Before the visit
Before our visit in Breiman
- 1
Measure the designated room space precisely
Confirm the exact dimensions, ceiling height, door and window openings, and send us a photo or sketch before our visit.
- 2
Verify the electrical supply and available circuit capacity
Check with an electrician that you have a separate, high-capacity circuit available for the compressor, or let us know if you need electrical work.
- 3
Prepare a drainage collection point outside the room
Designate a location outside the room for drainage collection and confirm there is a clear path for the drain pipes.
More districts for Cold & freezer room installation
Other services in Breiman
FAQ
Questions about Cold & freezer room installation
Why does a freezer room need an insulated floor when a chiller often does not?
At sub-zero temperatures the moisture held in a concrete slab freezes and expands, cracking tiles and lifting bases over time. A chiller room operates above freezing, so ice crystals do not form in the slab. A freezer room therefore requires insulated panels under the floor together with a vapour barrier that blocks rising ground heat and protects the structure over the long term.
What is the difference between electric defrost and other types?
Electric defrost uses heating elements fixed inside the evaporator coil; they warm the coil directly and melt frost build-up. Hot-gas defrost instead redirects warm refrigerant from the compressor back through the same coil. The choice between the two depends on room size, the required number of cycles and the type of goods stored; the site survey determines which method suits each installation.
Can two zones at different temperatures share the same footprint?
Yes. A partition of insulated panels separates the space, with each side using a panel thickness matched to its required temperature differential. Each zone has its own refrigeration unit and a door with a heated frame to prevent condensation. This arrangement is widely used in meat and fish facilities that need a chiller zone for short-term stock and a freezer zone for longer storage. The final design depends on the available floor area and the heat load of each section.
Does the position of the condensing unit affect how the freezer room performs?
Position has a direct effect. The condensing unit needs clean air and adequate flow to reject heat; if it is placed in a confined space or near heat sources the condensing pressure rises and the compressor works harder. In Jeddah, outdoor air also carries salt and dust that accumulate on the condenser coil over time. The site survey identifies the best location and the copper-pipe route, keeping each Mueller copper pipe run within thirty metres without welded joints.
Does the position of the condensing unit affect how the freezer room performs?
Position has a direct effect. The condensing unit needs clean air and adequate flow to reject heat; if it is placed in a confined space or near heat sources the condensing pressure rises and the compressor works harder. In Jeddah, outdoor air also carries salt and dust that accumulate on the condenser coil over time. The site survey identifies the best location and the copper-pipe route, keeping each Mueller copper pipe run within thirty metres without welded joints.
Our warehouse needs one freezer room for meat and another for poultry, can you separate them?
Yes, we design two separate rooms or one room with an internal partition and a separate evaporator for each zone, depending on your space and budget.
East Jeddah is much hotter, does the room need extra insulation?
Yes, east Jeddah's extreme heat requires thicker insulation and a stronger compressor to keep the target temperature stable and efficient.
Condensation and meltwater from the room are heavy, where does it go?
We install a robust drainage system with sloped pipes toward a collection point outside the room, and may add a drainage pump if the warehouse floor level is low.
The warehouse wiring is old, does the compressor need its own circuit?
Yes, the freezer compressor needs its own high-capacity electrical circuit, and a quick check of your existing wiring confirms whether the warehouse can support it or needs an upgrade.












































































