Desert cooler, proper duct

Evaporative (desert) duct installation in Harat Al Sham

Evaporative duct installation in Harat Al Sham, a historic area of old Jeddah, requires special study of older building roofs and narrow passages to determine duct evaporative system feasibility.

  • Sealed roof
  • Galvanised duct
  • Air changes

Clients We're Proud to Serve

Organisations and companies that trusted Alrabih with their projects.

  • Saudi Aramco
  • Ministry of Energy
  • Royal Saudi Land Forces
  • Royal Saudi Naval Forces
  • Al Baik
  • Centro Hotels by Rotana
  • King Abdullah Economic City
  • First Mills
  • Juffali
  • eXtra
  • Dr. Soliman Fakeeh Medical Center
  • Alesayi Motors
  • Abu Zaid
  • Water Desalination
  • Attieh Steel
  • SSCO
  • Creet
  • Emad Rizq
  • Alfaneyah
  • Rawat Alam Al Tasmeem
  • IBI Magix Arabia — Construction Services
  • Midtown for Construction
  • Petra Engineering Industries Co.
  • Hyrmas
  • Batterjee Medical College
  • Advanced Horizons Contracting Company
  • D.Metals
  • Benchbox — Masters of Space
  • Sadafco
  • Umm Al-Qura University
  • Saudi Arabian Drug Store (SADS)
  • Foamco
  • Ahmad A. R. Bin Afif Industries Co. (Sandwich Panel Factory)
  • Namariq
  • ALS

When you need evaporative cooler duct

  1. 1

    A large workshop or warehouse

    Large industrial spaces get very hot in Jeddah summers and split units are expensive to run there. An evaporative cooler with distribution duct brings air to work areas at lower running cost, provided the space is ventilated and not sealed shut.

  2. 2

    A majlis tent or seasonal space

    Outdoor majlis areas and seasonal tents do not suit split AC units because of the structure. Evaporative duct delivers a cool air stream as long as the space is open enough for air changes, which the survey confirms.

  3. 3

    Old duct with poor airflow

    Old sheet duct cracks over time and air leaks from the joints before reaching the space. On site we check whether the problem is leaking duct, poor distribution, or the cooler size itself.

Who it's for

  • Need to cool a large workshop at reasonable running cost

    We survey the workshop and check its ventilation, then run galvanised duct from the roof cooler to the work areas with exhaust openings that keep air moving through the space.

    Ask on WhatsApp
  • You have an outdoor majlis that needs seasonal cooling

    We check how open the majlis is and assess its structure, then design the duct route and exhaust openings so cool air reaches the seating area without humid air building up inside.

    Ask on WhatsApp

What the work covers

  • Weatherproof roof collar fitted
  • G90 galvanised duct runs
  • Branch and air outlet connections
  • Exhaust openings for air changes
  • Airflow check after start-up
Request a quote

How we work

How we work

  1. 1

    Site survey first

    We visit, measure the space and check how open it is, because evaporative cooling needs enough ventilation; without it humidity rises inside and the cooling effect drops.

  2. 2

    Plan the duct route

    We plan the main duct run, branches, air outlet positions and exhaust opening locations, and show you the layout before any work starts.

  3. 3

    Install duct and seal roof

    We open the roof, fit and seal the collar against leaks, then run the galvanised duct and hang it on proper supports so it does not sag.

  4. 4

    Start-up and test

    We run the evaporative cooler and check that air reaches every outlet and that the exhaust openings are working so fresh air is visibly moving through the space.

Planned duct or a quick run?

AlrabihThe usual way
Roof sealWeatherproof, sealed collarSilicone that cracks in heat
SheetG90 galvanisedUnspecified gauge
ExhaustSized openings for air changesLeft to chance
Space suitabilityConfirmed by surveyNot checked
Duct supportsFixed hangers along the full runDuct left unsupported

Some of our work

Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.

  • Galvanized rectangular duct trunk with branch takeoffs and round diffusers, hung from a black ceiling, a Carrier unit visible behind — interior finishing stage.
  • Round diffusers and a spiral duct trunk in a tiled stairwell service shaft.
  • Rooftop ductwork and an exhaust fan, with Jeddah buildings in the background.
  • Rooftop packaged AC units with rectangular duct transitions, city buildings behind.
  • Insulated rooftop duct run beside a packaged unit, a warehouse roof in the background.
  • A grid of round diffusers in an open-plan office ceiling, mid-construction.
  • An insulated rooftop duct elbow, against a mountainous backdrop.
  • Large insulated ductwork running along a factory ceiling, with workers visible below.
  • A yellow round diffuser mid-installation, with spiral duct and a suspended ceiling grid.
  • Duct insulation wrap in progress on a construction site, bare duct still exposed.
  • A black-painted duct trunk with round diffusers and track lighting, in a finished retail interior.
  • An indoor AHU unit connected to round ductwork in a mechanical plant room, exposed concrete ceiling.
Similar project? Send us the details

Customer reviews

What our customers say

4.8

From 10 Google reviews

  • Muhammadramzan 2641

    “MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”

  • shahzeb armani

    “Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”

  • Tawfik AlyawerLocal Guide

    “U can find all u need for air conditioning”

Read every review on Google

Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.

Worked with us? Leave a review

Service areas

We come to you anywhere in Jeddah

From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

Map of Jeddah by sector, with Alrabih's base in Al Aziziyah
Don't see your district?Message us. We most likely cover it.

What sets this district apart

Harat Al Sham is a historic area in old Jeddah, marked by tightly built old blocks with narrow, confined roofs and extremely tight exterior and interior passages and small window and roof openings. Duct evaporative cooling may not suit most old buildings here because space is so tight, but some redeveloped buildings or large shops might accommodate it. Galvanised duct needs a carefully routed path through very limited space, requiring extremely precise surveying and may not be practical in most cases.

Harat Al Sham lies in historic old Jeddah, a district of tightly built old blocks with narrow roofs and very limited open space.

Most old buildings here lack easily accessible roofs, and interior and exterior passages are so tight they cannot accommodate large-gauge galvanised duct.

The AC setup in Harat Al Sham

  1. 1

    Very limited possibility of roof cooler system

    Most old tightly built buildings here lack safe or accessible roofs for roof cooler installation because of their narrow, aged construction.

  2. 2

    Very limited interior and exterior spaces

    Interior and exterior passages in old downtown are so narrow they may not accommodate large galvanised duct runs.

  3. 3

    Engineering inspection essential before any installation

    Before considering any cooling system, we recommend thorough engineering inspection of the building, roof, electrical base and ventilation.

Before the visit

Before our visit in Harat Al Sham

  1. 1

    Confirm access for team and equipment

    Ensure passages and openings allow team and tools to enter without damaging the old building or neighbouring shops.

  2. 2

    Coordinate with neighbouring buildings and shops

    Tell neighbouring shop and building owners about the visit because shared spaces are so tight any activity affects their movement.

  3. 3

    Initial engineering inspection of roof and electrical base

    Before any detailed visit, we may recommend an initial engineering inspection by a specialist to determine whether any cooling system is feasible.

FAQ

Questions about Evaporative (desert) duct installation

Does evaporative cooling work in Jeddah in summer?

Evaporative cooling relies on water evaporation and weakens when humidity is high. In Jeddah, humidity is higher near the coast and lower inland. The survey decides whether the space and the season are suitable, which is why we do not start before visiting the site.

Why do exhaust openings matter as much as the duct runs?

An evaporative cooler pushes fresh air in continuously. Without an exit path, humid air builds up inside and the felt temperature rises. Properly sized exhaust openings keep air moving through, not piling up, and that is the core of how this type of cooling works.

What sheet do you use for the duct?

We use G90 galvanised steel sheet, which resists rust in Jeddah's humid and salty air. The duct sections are formed in our workshop before being taken to site, then hung on supports along the run to stop them sagging.

Can one cooler supply duct to more than one area?

Duct can be branched from one unit to more than one outlet, but each branch reduces the airflow at every opening. The survey decides whether the cooler has enough output for the total area, or whether a separate unit for each wing is the better answer.

Can evaporative cooler duct run through a false ceiling?

Evaporative cooling depends on continuous air movement and exchange, which requires exhaust openings in the same space the duct serves. A false ceiling restricts that flow unless dedicated openings lead air out of the building. The site survey decides whether the structure allows it, because the duct run and the exhaust are designed together as one system, not separately.

Does evaporative cooling suit the old buildings here?

In most cases, the old tightly built blocks here do not suit duct evaporative systems because roofs are narrow and passages extremely confined. We survey each site carefully to determine if the system is possible.

The passages are extremely narrow, how would you run the galvanised duct?

We need very careful surveying first. If passages are extremely narrow, we may not be able to widen spaces safely, and we may recommend alternative cooling solutions better suited to the site.

Old downtown humidity is high, does that affect evaporative cooling?

Yes, old downtown Jeddah has high humidity, especially because of the sea proximity and tightly built low-ventilation blocks. This greatly reduces evaporative efficiency, another reason the system suits few buildings here.

Buildings are old and roofs are weak, can they support a roof unit?

This needs precise structural inspection of the roof and frame. In most cases, old weak roofs cannot support additional unit weight, and we recommend engineer inspection before any installation.

The Jeddah corniche in cool weather

Start with a site survey

WhatsApp a photo and rough dimensions of the space, and we will book a survey visit in your district, Saturday to Thursday, eight in the morning to eight in the evening.