Central AC for apartments
Apartment central AC in Al Nur
In Al Nur, north Jeddah, apartment central AC installation requires precision in positioning the indoor unit within a tight ceiling void and distributing air quietly to avoid disturbing neighbours. Alrabih ensures the condensate drain runs clear of dampness and leakage between flats.
- Tight ceiling
- Sealed drain
- Quiet running
Clients We're Proud to Serve
Organisations and companies that trusted Alrabih with their projects.
When central AC makes sense in your flat
- 1
New flat before finishing
The finishing stage is the right time to install central AC. The ceiling is open and walls are ready for copper and drain routes, so there is no need later to cut plaster or damage finished surfaces.
- 2
Occupied flat where splits fall short
If splits leave hot and cold patches, or the noise bothers you at night, central AC distributes air evenly and hides the unit away from the room. A site survey decides whether your ceiling height allows it.
- 3
Your unit disturbs the neighbours
In apartments, neighbours hear unit vibration through shared ceilings and walls. We choose the indoor unit suspension point carefully and use flexible collars on the air outlets to absorb vibration before it reaches the building structure.
Who it's for
Living in a furnished flat and want to replace splits
We survey your ceiling void to see whether a concealed unit fits, then run copper and drain without disturbing the existing décor.
Ask on WhatsAppBuying a flat in a building under construction
We coordinate with the finishing stage to run copper, drain and ducts before ceilings and walls are closed, so every route stays fully concealed.
Ask on WhatsApp
What the installation covers
- Ceiling survey and unit position
- Mueller copper fully insulated
- Condensate drain with correct fall
- Air ducts and distributed outlets
- Line vacuum and start-up test
How we work
How we work
- 1
Ceiling and route survey
We measure the available ceiling void, decide where the indoor unit hangs, map the copper route and find where condensate drains without causing damp. The survey decides whether one zone or more suits the flat.
- 2
Run copper and drain
We run insulated Mueller copper in the void above the suspended ceiling and slope the condensate line towards the building drain or an external outlet, so no standing water causes odour or damp.
- 3
Fit ducts and outlets
We mount the indoor unit on vibration-absorbing hangers, route ducts to each room and place every outlet so air spreads evenly without blowing cold air directly onto anyone.
- 4
Vacuum, test and hand over
We vacuum the copper line to remove air and moisture, check all joints, then run the unit and confirm cooling in every room before we hand over.
A considered install or a hasty one?
| Alrabih | The usual way | |
|---|---|---|
| Indoor unit position | Set after measuring the void | Wherever it fits |
| Condensate drain | Calculated fall to building drain | May pool and cause damp |
| Vibration | Absorbing hangers, flexible collars | Reaches the neighbours |
| Air distribution | Outlets placed for even spread | Cold rooms and warm rooms |
| Salty sea air | Mueller copper, tight flared joints | Early joint corrosion |
Everything your AC needs, from one team
From system design and duct fabrication to installation, commissioning and maintenance.

Split AC installation
Request this service
Duct installation
Request this service
Central AC installation
Request this service
Duct fabrication
Request this service
Cold room installation
Request this service
Electro-mechanical works
Request this service
Chiller & AHU installation
Request this service
HVAC design
Request this service
AC repair & faults
Request this service
AC cleaning
Request this service
Refrigerant charging
Request this service
Central AC maintenance
Request this service
Chiller maintenance
Request this service
AC removal & refitting
Request this service
Duct cleaning & sanitising
Request this service
AC servicing by brand
Request this service
Operation & maintenance contracts
Request this service
AHU maintenance
Request this service
Fridge & freezer service
Request this service
Cold rooms
Request this service
Display fridges & chillers
Request this service
Factory HVAC
Request this service
Warehouse HVAC
Request this service
Villa & home HVAC
Request this service
Hotel HVAC
Request this service
School HVAC
Request this service
Hospital HVAC
Request this service
Mosque HVAC
Request this service
Mall & retail HVAC
Request this service
Restaurant & cafe HVAC
Request this service
Some of our work
Ductwork, rooftop units and diffusers, from work we've completed in Jeddah.
Customer reviews
What our customers say
- Muhammadramzan 2641
“MashaaAllah. Services are so good. Behaviour and kindness 100/100. Prices are less then Market. Fully recommended”
- shahzeb armani
“Wow. Prices are so comfortable. Outstanding services. People are so talented and nice”
- Tawfik AlyawerLocal Guide
“U can find all u need for air conditioning”
Your satisfaction matters to us! If you had a great experience with us, we'd love a 5-star rating and a kind review.
Worked with us? Leave a reviewService areas
We come to you anywhere in Jeddah
From Al Shiraa and Al Yaqout in the north to Al Thaghr and Al Quraiyat in the south, with our base in Al Aziziyah.

What sets this district apart
Al Nur's northern blocks comprise modern and mid-rise residential clusters with similar units stacked in upper and mid-level floors and narrow shared corridors between them. This construction means the internal ceiling height is constrained, and the indoor unit space is usually restricted to a bathroom or hallway, requiring careful planning to route the condensate drain outward without affecting the flat below. Sound also travels readily through shared walls, so we choose the unit position and ductwork to keep noise low.
Al Nur lies in north Jeddah, a modern residential district of mid-rise and high-rise apartments with narrow shared corridors.
Most Al Nur flats have a constrained internal ceiling height, and the indoor unit is typically mounted in the hallway or bathroom because living spaces are too tight.
The AC setup in Al Nur
- 1
Indoor unit in hallway or bathroom
Because of tight flat dimensions, the indoor unit sits in the shared hallway or bathroom to maximise available space.
- 2
Distribution ducts within constrained ceiling
Ducts run discretely beneath the internal ceiling without reducing headroom, distributing air quietly to bedrooms and living areas.
- 3
Safe drainage away from the lower flat
Drain lines route carefully outward or to an isolated sump to avoid leakage or dampness between the units.
Before the visit
Before our visit in Al Nur
- 1
Identify your preferred indoor unit location
Before the visit, send us photos of the hallway and bathroom so we can agree on the best spot that offers enough room with minimal disruption.
- 2
Confirm ceiling and exterior access
Check that the shared ceiling can be easily accessed and that the exterior wall is available for passing the drain line and pipes through.
- 3
Coordinate with neighbours about installation work
Installation work creates noise and activity in shared corridors, so inform neighbours in advance to prevent misunderstanding.
More districts for Apartment central AC
Other services in Al Nur
FAQ
Questions about Apartment central AC
Is there enough ceiling space in a flat for a central unit?
It varies between flats. Slim ceiling cassettes need less void depth than full ducted units. A site survey measures what is available and decides the right type; if the corridor ceiling is too shallow we look at a storage room or bathroom ceiling instead.
Is one unit enough for the whole flat or do I need more?
It depends on the flat's area, room layout and how much sun each side receives. Two- and three-bedroom flats can sometimes work with one unit and well-planned ducts; larger flats or those with separate zones may need two. The survey decides.
Where does the outdoor unit go when the flat has no large balcony?
Options include the shared roof if the building rules allow it, a facade bracket away from neighbours' windows, or the balcony if it can take the load. We review the building's rules before recommending any position.
Jeddah's air is very humid; does that affect the condensate drain?
Yes. In Jeddah the indoor unit produces more condensate because of the high humidity. We make sure the drain line has enough fall, that the horizontal run before it drops is not too long, and that the outlet does not conflict with other flats' drainage in the building.
Can the flat be split into two zones with different temperatures?
It is possible using two separate indoor units or by adding variable-flow dampers on the duct runs. The right choice depends on the flat's layout and the ceiling void available in each zone. A site survey decides which approach suits your room arrangement.
The corridors here are very tight, how do you fit the indoor unit?
We position the indoor unit in the hallway or bathroom, and confirm the best spot with you beforehand that keeps movement unobstructed and noise low.
How do you prevent water leakage into the flat below?
We survey the drain route carefully before installation and angle the condensate pipes correctly toward the exterior or a safe drainage system, using sealants to prevent leakage.
Shared walls carry noise easily, will the unit be loud?
We place the indoor unit away from bedrooms and mount it on vibration-isolating brackets, using quiet ductwork to minimise noise for neighbours.
The ceiling is very low, does this affect installation?
Yes, low ceilings require a compact indoor unit and tight ductwork design. We measure the available space and confirm the unit fits the height before ordering.